APC Powerchute Could not connect to Host over the network
I am trying to connect the Powerchute network shutdown software to VMware ESXI V7 and I get the message: "Could not connect to Host over the network". I have re-created the certificate on ESXI,...
View ArticleCyberpower UPS floating charge 90-100%
I have a CyberpowerOLS3000ERT2U. The UPS seems to be floating its charge between 90-100%. This UPS is now coming up to 4 years old. We replaced the batteries thinking this was the cause and it has made...
View ArticleSomeone need free APC batteries?
I have 6 lightly used RBC55 batteries. I replaced the batteries and then the unit failed. They were in use only for a couple of months. Free for local pickup in Milwaukee, if you want them shipped, you...
View ArticleEaton 9PX 8000i Firmware Upgrade
Hi there.Is there any support resource for the CORRECT upgrade path for a Network-MS technical level 17 JA card?We're having issues with SNMP setup and it appears the later firmware resolves these...
View ArticleEaton 5P 650VA - shutdown with empty log
Hi,we have a fairly new (6 months old) Eaton 5P 650VA running latest 03.18 firmware. To it we have connected a router, switch and a Synology NAS - total load is about 30%UPS is also connected to same...
View ArticleIs it a good idea to run UPS using 3rd party battery?
I have a suburban home where the power supply isn't very stable. My current UPS is APC 1500Pro. With its builtin battery, my network device including surveillance cameras can last 3 hours after the...
View ArticleIs it a good idea to run UPS using 3rd party battery? (updated with pic)
I have a suburban home where the power supply isn't very stable. My current UPS is APC 1500Pro. With its builtin battery, my network device including surveillance cameras can last 3 hours after the...
View ArticleUPS recomendation for Low power long run time
There has been a thread recently about swapping out Batteries in UPSs to extend runtime (eg:swapping 7Ah ones with 14 Ah ones to double run time). Manufacturers tend to say don't consider this, get a...
View Article"Battery Near End of Life" after new batteries installed in APC SMT1500RM2UC
We have 2 APC rack units. Both batteries were replaced.UPS Model: SMT1500RM2UC Battery Cartridge used: APCRBC159 Shouldn't this cartridge replace all the batteries in the UPS?We were able to clear the...
View ArticleEaton 9130 No Outlet Power On Battery
I have a Eaton 9130 I bought refurbished with new batteries less than 1 yr old. The unit has been working flawlessly up until a recent power outage where the utility power cut out (for less 4 seconds),...
View ArticleEaton 5P550R No power when plugged in.
Bought a Eaton 5P550R 550VA/420W off of ebay. Seller indicated it was pulled because it needed new batteries. So it did not come with batteries.But the main issue Im having is that it will not power on...
View ArticleCyberPower UPS and Server Power
Hello,We have a CyberPower UPS with an RM card, and a server connected to the UPS. We have PowerPanel Business Remote software on the server for management. We know that there is a setting in the BIOS...
View ArticleWhat Do You Think the Future of “IT in the Warehouse” Will Look Like?
According to the WSJ Opens a new windowwarehouses are turning more robotic than ever. And so, more investment in devices to keep those robots running is increasing. Is this job security for you, the IT...
View ArticleEaton IPM Software
Hi, We recently purchased Eaton IPM V2 software and setup an VM appliance. We then setup some automation to shut various VM services down via it. The Issue we have is once VMware shuts the Eaton...
View ArticleIs anyone using a Powerware 9315 UPS 750 KVA UPS - 400V/480v system or similar
Is anyone using a Powerware 9315 UPS 750 KVA UPS - 400V/480v system or similar
View ArticleWarning message on UPS persists
Hi Everyone,I am operating a couple of APC Smart UPS 1500 units.Recently I had to replace the batteries in my UPS units.After replacing the batteries I noticed this message on each unit -In an effort...
View ArticleAPC SMX1500RM2UC monitor software
I have 2 of these APC SMX1500RM2UC. What exactly am I supposed to monitor them?I have both connected to my LAN, and they have IP addresses.But when I go to the IP address via browser, nothing...
View ArticleEaton ups restart
I have a Eaton 9E 1000i ups. I want it to shutdown connected outputs after 1min when power is cut from input and then after that i want UPS to be shut down. If the power comes back, i want UPS to start...
View ArticlePower System Error - 02000 followed by Internal RBC disconnected
Hi, I have a SRT6KRMXLI which displays 2 error:Power System Error - 02000Contact Customer Supportfollowed byInternal RBC disconnected Of course I contacted them, and of course they said to bring it in....
View ArticleUPS / Battery selection for "extreme" runtime (5-6 hours) for low power (
This question was asked and answered back in 2018, I was wondering if there was much advancement in the last 5 years? I can't seem to find a really good solution.