Need proper configuration of IPM/IPP with the new M2 Network management cards
We have 2 new 9XP Eaton UPS units with the new M2 Network Management card. The 2 units are configured in a parallel redundancy.1) Each of the network IPP "clients" has "registered" on both units under...
View ArticleHP R5000 UPS Connection Problems
Hello! We have two HP R5000 (rebranded Eaton?) that constantly losses either network connection or the connection to the UPS itself. We’ve already upgraded the Firmware to the version (1.12.002 /...
View ArticlePowerChute Network Shutdown Questions?
I'm trying to get PowerChute properly installed and configured.I can't seem to sort out the following:How to enable shutdown on multiple hyper-v hosts, must i install it on each host? Seems silly.Do i...
View ArticleTripp Lite SMART1500RM2U: quiescent power draw, fan noise, odd behavior, etc.
I have a Tripp Lite SMART1500RM2UN (SMART1500RM2U w/ WEBCARDLX) which appears to draw around 45 watts with no load, even when turned off (plugged in, of course). Well, 45W is apparently enough to raise...
View ArticleEATON 5SC1000 battery error still after replacement
Hello Guys,please i need help with my eaton 5sc1000, it has the following problems1. it beeps with bat and exclamation in triangle on lcd screen when powered on2. when main power is out its switches to...
View ArticleSilent UPS for Recording Studio
To Whom It May Concern,I am contracted to wire up the IT side of a recording studio. We initially deployed an APC SMC1500-2UC for the Mac Mini and supporting I/O hardware. However, after the client has...
View ArticleGenerator, UPS, ATS and equipment with two power supplies
Hello,Kindly ask your help in order to build a diagram with the following components:- a single line from electricity distribution company;- a single generator;- an ATS;-a single UPS;-an equipment with...
View ArticleEATON 5p Firmware stuck
Hello everyone, I got an EATON UPS 5p 850 (so no warranty) and tried to update the firmware but, after waiting almost an hour, it showed nothing on the screen and only the green logo was alight. So I...
View ArticleEaton 5PX - Communication with device has failed
Hi all,I need some help with a UPS communication connection problem.We have the following configuration:Model: 5PX3000RT2UP/N: 9210-8128-00PWindows 10 Ent 2016 LTSBIntelligent Power Protector in...
View ArticleHow do I get Tripp Lite SmartOnline 1000rtxlcd2u to charge a low battery?
I've got 2 of these units and 4 different cells I know to be good. Used, and currently low, but not bad batteries. On the better set of two they read 9 and 6 v, because they are low. When grouped, the...
View ArticleEATON POWERWARE 9125 turn OFF problem
Hi , my UPS EATON - POWERWARE 9125 does not want to turn OFF from STANDBY mode .The green LED ~ flashes proof that it is in standby mode.Are you helping me with this problem?Do you have a service...
View ArticleWhere can I buy very specific Power Adapters?
I moved and I have several device for which I have a lack of power adapters.I purchased some digital calipers and I am able to measure the hole size for the adapter, but now that I have that...
View Articleeaton 5P650IR & car battery runtime problem
so i bought a new 5P650IR. first thing i did was removed the internal batts and hooked up my 12V 75aH optima yellowtop car battery (deep cycle resistant)anywayat 25W load it only runs about 90 mins,...
View ArticleEaton 5PX 2200 fan fault 0x007
I have an Eaton 5PX 2200 that is out of warranty that had a fan fail, displaying fan fault 0x007.I ordered two identical Sunon MagLev ME80251VX-0000-G99 DC 12V 1.9W 3-pin Fans from ebay.I replaced both...
View Article3 times the price for the same UPS capacity
I'm spec'ing a new rack or two, to host 20 headless remote workstations. Each system' real-life consumption at absolute 100% utilization is 450W, so 9KW total @ 120V.Taking a quick look at APC's...
View ArticleCyberpower UPS advertises, but doesnt have programmable outlets?
UPS Model: OR2200LCDRTXL2U (Firmware: BF00801M2R1)RMCARD205 Firmware: 1.3.4Cyberpower website advertises "Programmable outlets" to prioritize outlets to keep on when on battery. Couldn't find this...
View ArticleEdit battery capacity Ah on Eaton 5CS 1000i
please assist me any software to enable my modify battery capacity for Eaton 5CS up. i recently swap the battery with Li ion battery with higher Ah but still get low runtime.
View ArticleWhich Eaton UPS for a small network
A couple of years ago, I bought a few Eaton 5px2200 Netpack UPS's for various clients. However they were about 30% cheaper back then. Prices seem to have gone up a lot since then.I am looking to get a...
View ArticleTripp-Lite UPS power goes off and I manually have to power cycle it
Tripp Lite OMNI1500LCDT which I use in a small MDF that has 2 Meraki switches on it.I come in this morning after the frantic "network down" message (at the dentist..oh joy as he's probing at my gums)...
View ArticleAPC device management
I've been looking into some soft of software to manage my fleet of APC devices, but many of them that I come across are discontinued. The only thing that I can find to purchase is something like this....
View Article