Copy Eaton IPP configuration

Is it possible to copy the IPP configuration from one Windows server to another?

View Article


HP R/T3000 G2 UPS Software

Hi Guys,I'm looking for the software to install on a HP Proliant DL325 Windows 2019, for a HP R/T3000 G2 UPS. If anyone can point in the direction would be most grateful.Thanks all.

View Article


Eaton 9130 log retention/rotation

We have 2 Eaton 9130 3000 units with each having a Eaton NetworkMS card installed. The measurements log for those is extremely small, only keeping 340 lines of data. that means if the measurement time...

View Article

1 UPS 3 servers 2 PS each

Hello allafter years of explaining that our old UPS system is horribly out of date, I have been allowed to purchase a new APC UPS. Currently, our old system is two controllers and multiple batteries,...

View Article

Shallow (15 inch) 2200va rackmount UPS?

I'm looking to mount a UPS in a NEMA cabinet that has a hinged front so get behind the equipment.  I've got about 15 inches from the rack rails back to work with.  I've looked at the usual suspects and...

View Article


Eaton 9355

I have five Eaton 9355 UPS, 20/30 kVA units.I get Notice #248 On Generator.  The unit is connected to the commercial power.  How to I clear that notice?Where could I obtain a list of Notices, and...

View Article

Tripp Lite UPS with Auto Probe for small DCs

A while back David from Tripp Lite highlighted the availability of an "Auto Probe" feature to cycle ports or port groups based on Ping failure. Looking for a recommendation for an alternative to an APC...

View Article

TrippLite SMART1500RMXL2Ua beeping with warning exclamation mark

I came into work this morning to discover that one of our new TrippLite UPSes had shutdown. I was able to turn it on, but it keeps an exclamation point and a continuous beep every few seconds.Model:...

View Article


Eaton IPM 1.66 update, communication with VCenter 6.5 appliance question

My Eaton IPM appliance was crashing. I am loading a new OVF. Adding the Infrastructure Connector for VCenter 6.5. "Communication Failed"It fails on the VCenter root password. It fails whether I use IP...

View Article


For Eaton IPM to shut down ESXi, what ESXi role permissions are required?

I'm tasked with configuring IPM 1.65 to shut down the virtual machines hosted by a standalone VMware ESXi v6.7 host, then to shut down the host itself. To be clear, this host is the free version, not...

View Article

Eaton 5S Output Waveform and Problems on Battery Supply

For the Eaton 5S, how close is the output waveform on battery to a pure sine? I've seen comments on the web that its stepped as well as square. Also, any real world experience with problems using...

View Article

How to solve Voltage Sags and Distorted Input for High Wattage Server Farm?

Hi all,We have 2 3000VA UPS's (w/ addtl battery stacks) that support our critical infrastructure and servers. Runtime is estimated at 1hr30min. These UPS's frequently (2-10 times a month) report either...

View Article

Eaton ups

I have Eaton ups shows error low inverter voltage , request for assistance on how to fix this

View Article


Ups and power fluctuations

Dear all, I have nine branches that I support of late we have fluctuating power/electricity and I experience break down of different branches,' UPS. My question is, can a ups be affected by power being...

View Article

Which UPS for 2 servers and 1 Sybology NAS

Hi guys, After the last power outage, one of my SMB customers finally decided to replace his old APC Backu-UPS.:)He has 2 physical HPE servers and 1 Synology NAS. I tried to found one, which is able to...

View Article


ATS and UPS configuration

APC has an ATS FAQ (https://www.apc.com/us/en/faqs/FA156201/) where they state that only double conversion on-line UPS should be used behind an ATS (line-interactive UPS is not recommended).Does this...

View Article

Automatic VxRail cluster shutdown with Eaton IPM

Hello, Is there posibility to gracefully shut down a DellEMC VxRAIL with 3 nodes configuration connected to Eaton UPS with basic licence of IPM V1.66.Thank you for your reply.Wassim

View Article


Help needed to Windows server auto-shutdown with EATON 9PX8000 network UPS

Hi, in my IT room, I have two servers and both are connected to a very large, whole room, EATON 9PX8000 network UPS. On both Windows 2012 R2 Server, I installed the EATON Intelligent Power Protector...

View Article

Recommendations for Desktop UPS

Hi Everyone, thanks for taking a minute to read this post. I have been a long time (25+ years) APC customer for desktop UPS needs, but I am decidedly against the recent changes to APC's (desktop)...

View Article

TrippLite SMART1500RMXL2UA won't bind to server NIC of choice

Greetings everyone,I had a challenge today, still unsolved. I built a new server and plugged in a SMART1500RMXL2UA with a USB cable. When I couldn't get the server to recognize the UPS I called...