N1C vs Eaton vs APC
We are replacing a UPS system in our server room. It currently runs about 700 - 800 watts. I have always used Eaton or APC in the past, but I connected with an N1C salesmen recently and their battery...
View ArticleEaton 9 PX Ki 11kva wont come on when connected to normal ac source
I have an Eaton 9PX ups, of late it gave a no battery message, on starting it showed a 95% charge with 1 EBM detected and then a few seconds later showed that theres no battery message and followed by...
View ArticleDevice to remotely toggle electricity to devices
Hello all,I have one or two devices in our networking closet which occasionally glitch and need to be unplugged and plugged back in. I'd like to be able to log into something from my desk and toggle...
View ArticleEaton 5P650IR powers down and cannot be restarted
Last night the UPS was showing normal operation with 100% battery charge and a ~50W load. This morning the display is completely off, no LEDs are on, the output is off, and it does not restart when the...
View ArticleEaton IPP notifications problem
Hi,I've just acquired an an Eaton 5P, which I've connected via USB to a Windows 2012 R2 server running IPP as shutdown controller. Another Windows 2012 R2 server runs IPP as a 'slave'. The network the...
View ArticleEaton UPS not loading elements after power on
Hi guys. We had a power down on the whole building so after some time, our 2 UPS shutdown too. When the power came back, the 2 UPS turned on. UPS A loaded the elements right away but UPS B didn't load...
View ArticleEaton 9355 cannot detect battery. I can read battery voltage on screen.
The UPS cannot see the onboard battery, even though I can use the screen to readout the battery voltage. The error says Battery Breaker open. Any help please?
View ArticleEton UPS 2200
Eton UPS shown max charge volt error ,what the main cause of this errorwe have 9 UPS with this defective error this month.how to check ups healthy to avoid damage .
View ArticleAPC local network management interface-to-UPS communication issues
We have an APC Symmetra LX UPS system in our server room. Last night we started getting alerts with the error The local network management interface-to-UPS communication not established We can...
View Articleeaton 5sc 1000i
having a problem finding an answer so ill post here also tried eaton support but no answer yet.i got the eaton 5sc 1000i ups and the device firmware is 01.12.0020 i searched to see if there are updates...
View ArticleEaton 5P Fault log empty
Is there any way to figure out what is logged to the fault log? We have a 5P 650i that has sent several events via RS232, but the fault log is empty. I am trying to understand which events are logged...
View ArticleConstant clicking/tripping on Smart-UPS 1500 unit
Hi All,Our Fujitsu Smart-UPS 1500 unit decided to trip out on Christmas Day (of all days). I got to the unit on the day and the display panel showed all the lights flashing and it was making a clicking...
View ArticleWhich UPS for Hyper-V?
Hello,I'm looking at replacing a dumb UPS whose batteries have failed with a network managed UPS.The UPS purpose is to protect from short outages (a few minutes or local utility power infrastructure...
View ArticleEaton 5P battery fault error 0x607 (Part II)
Way back in June 2018 I asked a question about my Eaton 5P 650 UPS and the 0x607 battery fault error it was reporting.It took eighteen months, and it's far too late to update the previous thread, but I...
View ArticlePreventive maintenance plan for UPS?
Can someone provide me a preventive maintenance plan for UPS.
View ArticleEaton IPP "Full data acquisition has failed"
Ubuntu 16.04 server, Eaton 9PX 1500i RT 2U connected with USB, just installed Eaton IPP.I can log in to the IPP Web page. Quick scan finds the UPS device, and even gets the serial number right. However...
View ArticleIssue with UPS eaton 5E 2000i usb companion software.
Hello everyone, I have an issue with the usb companion software provided by eaton for my UPS 5E 2000i, everything connects and works just fine the issue is that I get a "Navigation to webpage was...
View ArticleEaton IPM 1.67 VA - refresh loop?
Hi,I have recently installed the IPM 1.67 Virtual Appliance and have been experiencing a problem where once I'm logged in, the web page just keeps on reloading / refreshing every second. In the...
View ArticleAPC UPS Spec
We have just placed an order for a new server, and I am looking to spec a UPS to go with it. Everyone I have chatted to offline has recommended APC, so I have decided to go with them. (We also have APC...
View ArticleAdapter for PDU input cable to fit into a new UPS
Hi Spiceworks,I have two APC AP8870 PDUs that currently hook into a Symmetra LX unit. I need to remove the Symmetra and install a different unit, a Tripp-Lite. The plug on the PDUs is an L14-30 plug. I...
View Article